Validation Intelligence
TraceProof Workspace
Ingest requirements, BMS properties, tests and evidence — then map them into proof.
Project setup
Three inputs before the engine can reason
Requirements, BMS properties, and known tests/evidence are available here. Expand to manage sources.
Expand
Project setup
Three inputs before the engine can reason
Requirements, BMS properties, and known tests/evidence are available here. Expand to manage sources.
Requirements
LoadedCustomer specs, RFQs, system requirements, market requirements.
4,042
requirement candidates
BMS technical properties
Needs reviewFunctions, signals, limits, operating modes, failure states, diagnostics.
cell_voltage
SOC
contactor_state
fault_flags
Known tests & evidence
LoadedTest catalogue, standards, homologation docs, reports, previous results.
286
test/evidence assets
Coverage Breakdown
Requirements with tests74%
Requirements with evidence58%
Acceptance criteria complete69%
Source Asset Library
- BMS function/property modelreview
- Internal HIL test catalogueloaded
- ISO 16750 electrical testsloaded
- Previous homologation evidence286 docs
Proof package
Ready for customer review
Generate a first-pass proof package with requirement status, mapped tests, reusable evidence, and open validation gaps.
Requirements analyzed
4,042
+91% extracted with source links
Covered by existing tests
612
59% reusable validation scope
Open proof gaps
184
acceptance criteria / evidence missing
Estimated effort saved
€42k
vs. manual first-pass review
Requirement Intelligence
Click a row to inspect mapping suggestions.
FulfilledPartialGap
| Req ID | Extracted property | Recommended / matched test | Status | Confidence |
|---|---|---|---|---|
| REQ-BMS-014 | Overvoltage detection within 100 ms | TEST-OV-003 · HIL threshold injection | Partial | 87% |
| REQ-BMS-022 | CAN diagnostic DTC after isolation fault | Recommended: isolation fault injection | Gap | 73% |
| REQ-BMS-031 | Cell voltage measurement accuracy ±5 mV | TEST-VS-011 · voltage sweep | Fulfilled | 94% |
| REQ-BMS-047 | Recovery after supply voltage dip | ISO 16750-2 voltage dip profile | Partial | 81% |
Coverage Breakdown
Requirements with tests74%
Requirements with evidence58%
Acceptance criteria complete69%
Source Asset Library
- BMS function/property modelreview
- Internal HIL test catalogueloaded
- ISO 16750 electrical testsloaded
- Previous homologation evidence286 docs
Proof package
Ready for customer review
Generate a first-pass proof package with requirement status, mapped tests, reusable evidence, and open validation gaps.